Support

Support

Configure your individual carpet, order samples or contact us directly!
Personal advice
Phone: +49 711 34 02-0
Acoustic tiles | Plankx

Block

Rustic vitality or modern chic: in the "Block" design category, PLANKX makes room for exciting visual effects of stone and concrete.
Pure originality.
A design that captures the vivid and varied structure of untreated stone - with cracks and typical patterns it looks like an authentic concrete surface. From calm, understated concrete structures or warm optical effects of chalk surfaces in a fashionable vintage look to textured surface designs, Block creates uniform floor areas with fascinating energy.
Ordering of Samples & Texture files
Please select a colour.
Download texture files for all colours
1301 Block
1301 Block
1302 BLOCK
1302 BLOCK
1303 BLOCK
1303 BLOCK
1304 BLOCK
1304 BLOCK
1307 BLOCK
1307 BLOCK
1308 BLOCK
1308 BLOCK
1309 BLOCK
1309 BLOCK
Product features
G
Wearability EN 1307 (commercial high)
The wearability is determined on the basis of density, hardness, flammability as well as acoustic and thermal properties. Depending on the wearability, floor coverings are divided into strains classes that provide information on possible fields of application.
T
Flammability EN 13 501 – 1 (CFL-S1)
The European standard defines uniform classes from A (non-flammable, not for carpets) to F (highly flammable) for the fire behavior of building materials. Contract areas often require the classes Cfl and Bfl (fl = flooring). The fire classes B, C and D are divided into classes s1 and s2. A product in the same fire class performs better with s1, since the smoke development is lower here than in s2.
k
Comfort class EN 1307 (LC1)
The comfort value of textile floorings is calculated according to the European norms on the basis of parameters (weight or thickness of the pile material used as well as the number of nubs or loops). A higher LC value (= Luxury Class) means a higher comfort value. The more crowns the symbol shows, the more luxurious the textile flooring is.
q
Rated sound absorption coefficient aw
The sound absorption coefficient was determined in accordance with ISO 354 and indicates how large the absorbed portion of the total incident sound is.
p
Light fastness ISO 105-B02
The symbol indicates that the textile floor covering meets the basic requirements for light fastness (>=5, for pastel shades >=4) in accordance with the test method EN ISO 105-B02.
s
Footstep absorption improvement coefficient ISO 140-8 DLW
The footstep absorption improvement was determined according to ISO 140-8 DLW. Basically, all textile floor coverings have excellent sound and footfall absorption properties.
e
Thermal permeability ISO 8302
If a textile floor covering is laid on a floor heating, its thermal permeability should be as small as possible. Usually, the value should be less than 0.17m²K / W. The symbol indicates that the textile floor covering can be used in combination with an underfloor heating.
M
Surface resistivity ISO/DIS 10965 ROT
Particularly contract areas often place higher demands on the electrical behavior of floor coverings. Textile floor coverings are considered to be electrostatically dissipative if the surface resistivity is ≤ 109Ω.
Z
Skid resistance
According to EN 14041, floor coverings must comply with certain safety aspects, including the slip resistance. To be equipped with the DS symbol, the textile floor covering must have a dynamic coefficient of frictional resistance of >0.3 in a dry and unpolluted condition.
L
Electrostatic loading EN 1815
Particularly contract areas often place higher demands on the electrical behavior of floor coverings, e.g. in computer rooms. The symbol indicates whether the textile floor covering is conductive.
7
Flammability EN 13 501 – 1
The European standard defines uniform classes from A (non-flammable, not for carpets) to F (highly flammable) for the fire behavior of building materials. Contract areas often require the classes Cfl and Bfl (fl = flooring). The fire classes B, C and D are divided into classes s1 and s2. A product in the same fire class performs better with s1, since the smoke development is lower here than in s2.
Available as
Tile